9
No. Name Feature Format
1 DC IN Power cable connection to the body
2
NTSC/PAL
VGA/TV
Select the video input format
Select the video output format
DA-2
3
RS485
DIO
PTZ Camera Control Connection
Sensor/ Relay Connection
Terminal
Block
4 Ethernet
Network Connection(ADSL, Cable Modem, Ethernet
10/100 Base-T)
RJ-45
5
G
-OUT VGA Monitor or LCD Monitor Connection D-SUB 15P
6 AUDIO IN Audio Input Connection(Line Only Input) RCA
7 AUDIO OUT Audio Output Connection(Line Only Output) RCA
8 TV CCTV Monitor Connection(Divided Screen) BNC
9 SPOT
CCTV monitor connection to output image from the
channel generating an event signal(Full Screen)
BNC
10 CAMERA IN Video Camera Connection BNC
11 LOOP OUT Video Signal loop-back Output Connection BNC
2-2. Installation and Connection
[Figure 2-1. eSync M Series Basic Connection and Device Connection]
2-2-1. Basic Connection
By referring to above [Figure 2-1. eSync M Series Basic Connection and Device Connection. Connect the
CCTV camera, CCTV monitor (or VGA monitor), and USB mouse to the DVR and set up CONFIG SWITCH.
Connected Device DVR Terminal
1
CCTV camera Rear Video Input
2
CCTV monitor Rear TV
3
VGA Monitor / LCD Monitor Rear VGA-OUT
4
Mouse eSync M Series: Front USB / SM/SH-Series : Right Side USB
5
CONFIG SWITCH Rear NTSC/PAL or VGA/TV Setup
※ Refer to a further description of CONFIG SWITCH below.